Home

Mogen clamp vs Gomco

Objectives. 1) To compare the Mogen and Gomco clamps with regard to pain experienced during neonatal circumcision, and 2) to assess neonatal circumcision pain with and without dorsal penile nerve block (DPNB). Design/Methods. A randomized, controlled, nonblinded clinical trial; 48 healthy, full-term infants were randomized into one of the following four groups: Gomco vs Mogen with (+) or. the Gomco clamp or the Mogen clamp. The Gomco approach is associated with more pain and a longer operating time compared with the Mogen approach.2 There is scant additional information on the differences in procedural complications, outcomes, and revision rates after the use of either method. The Gomco clamp consists of The GoMo study: a randomized clinical trial assessing neonatal pain with Gomco vs Mogen clamp circumcision. Am J Obstet Gynecol. 2015 May;212(5):664.e1-8. doi: 10.1016/j.ajog.2015.03.029. Epub 2015 Mar 17 Objectives: 1) To compare the Mogen and Gomco clamps with regard to pain experienced during neonatal circumcision, and 2) to assess neonatal circumcision pain with and without dorsal penile nerve block (DPNB). Design/methods: A randomized, controlled, nonblinded clinical trial; 48 healthy, full-term infants were randomized into one of the following four groups: Gomco vs Mogen with (+) or.

A Comparison of the Mogen and Gomco Clamps in Combination

  1. Mogen clamp and DPNB did not cry at all during the procedure. Conclusions. DPNB is effective in reducing neonatal circumcision pain with either the Mogen or the Gomco clamp. For a given anesthesia condition, the Mogen clamp is associated with a less painful procedure than the Gomco. The Mogen clamp with DPNB causes th
  2. ed that the Mogen clamp is associated with less pain and discomfort, and is safer, faster, and preferred by surgeons [Sinkey 2015]. Surveys from various providers show that Mogen clamp was.
  3. Call to Action: Clinical trial of Mogen vs Gomco circumcision clamps at the Good Samaritan Hospital in Cincinnati, Ohio The TriHealth Good Samaritan Hospital in Cincinnati , Ohio, is currently running a clinical trial to find which is better, whether the mogen clamp or the gomco clamp, to perform newborn male circumcisions
  4. Boys circumcised with a Mogen clamp had less than half the heart rate increase and total crying time of infants circumcised with a Gomco. Blood oxygen levels also were higher in the Mogen infants, a sign that they suffered less stress, said Dr. Hema N. DeSilva, director of neonatology at St. Francis Hospital and Medical Center, the study leader.
  5. Re: Gomco vs. Mogen Brain Dump. My son, who was born in the 1980's, was routinely circumcised at 2 days by his pediatrician using a Gomco clamp. (I later found out) Not particularly tight either. When his son was about to be born, he asked me about his own circ and I explained to him it was by a Gomco clamp. He then asked his pediatrician if he.
  6. Re: Gomco vs. Mogen Brain Dump. John S. 2/15/20 #294. Le Xip, It seems logical that the Mogen shield method is more predictable in its results than the old Gomco clamps. Some tragic mistakes have occurred with the old Gomco's especially when the parts were not perfectly matched

The GoMo study: a randomized clinical trial assessing neonatal pain with Gomco vs Mogen clamp circumcision. Am J Obstet Gynecol. 2015;212(5):664.e1-664.e8. 26. Liu Y, Huang X, Luo B, et al. The Gomco clamp was used for about 55% of circumcisions and 44% were performed with the Mogen clamp. Complications were rare, occurring after just 3.8% of all circumcisions. All complications were. OBJECTIVES: Elective newborn circumcision, one of the most common surgical procedures in the world, is often performed with either the Gomco clamp or the Mogen clamp. Our aims were to determine differential circumcision revision and complication rates due to surgical technique and differences in outcomes when residents versus attending physicians performed the procedure A total of 168 maternal surveys were completed, with 98.7% maternal satisfaction in Gomco vs 98.9% in Mogen. There were no reports of bleeding after discharge or circumcision revisions in either group to date. Conclusion: Mogen clamp is associated with less neonatal pain physiologically by significantly lower percentage change in salivary.

The sample size was calculated using R statistical software (version 2.15.3; R Core Team 2013) 27 and the extension package samplesize. 28 The original sample size calculation was based on the results of a previous clinical trial of Gomco and Mogen clamps. 6 We considered a 60% reduction (from 0.57 [0.8] μg/dL) in salivary cortisol in the. The Gomco clamp is one of several devices currently used for neonatal circumcision. Invented around 1935 by Dr. Hiram Yeller, an obstetrician, and Mr. Aaron Goldstein, an inventor, it has been in continuous use for more than 70 years. (The clamp gets its name from the company that originally manufactured it, the Goldstein Manufacturing Company.) A 1998 survey found that the Gomco clamp was the preferred technique by 67% of American physicians, whereas Plastibell was used by 19% and the Mogen clamp by 10%. Mogen clamp. The Mogen clamp is a surgical instrument which permits rapid circumcision. It is most often used in the newborn period, particularly for Jewish ceremonial circumcision. Yes, Gomco and Mogen are both clamp types. Some of us love the resultant witness scar, usually a darker ring. Impossible to find Gomco in UK. Mogen a lot easier. The big difference is that a gomco produces a genuine circumcision (circular incision) around the entire penis while the mogen creates a v-shape scar on the underside (or in rare.

Gomco Versus Mogen: Which is Best? A Randomized Controlled

The Gomco and Mogen clamp methods utilize a probe to separate the foreskin from the head of the male member. Doctors then use a clamp to stop the flow of blood, and then a scalpel to remove the foreskin. The plastibell technique is quite different. After separating the foreskin from the head using a probe, the doctor places a plastic bell under. 5:45 Streaming Video] Here, Dr. Brendan Duterte demonstrates circumcision with the Mogen clamp. Dr. Duterte is a pediatrician at Santa Clara Valley Medical Center in San Jose, California and has nearly thirty years of experience in medical practice

Call to Action: Clinical trial of Mogen vs Gomco circumcision clamps at the Good Samaritan Hospital in Cincinnati, Ohio. May 10, 2013 AAP, Circumcision, Complications of circumcision, Harm of circumcision, Human Rights, Medical Community, Studies Circumcision, Gomco Clamp, Mogen Clamp, Trihealth Good Samaritan oculus21 Mogen clamp. In 1954, Rabbi Harry Bronstein, a Brooklyn mohel who'd previously invented the Nutech clamp - that's the one that looks like a hacksaw - invented the Mogen clamp. Mogen means shield (and in fact what we call in English the Star of David is Mogen David in Hebrew, the Shield of David. Mogen clamp is associated with less neonatal pain physiologically by significantly lower percentage change in salivary cortisol, lower heart rate, and mean arterial blood pressure. There was no difference in CRIES scores. Mogen clamp circumcision duration is significantly shorter than Gomco clamp

Circumcision is the surgical removal of all or part of the distal penile foreskin (prepuce). This topic will review the patient selection, analgesia, and techniques for neonatal circumcision, including the Gomco clamp, Plastibell device, and Mogen clamp. Discussions of the risks and benefits of neonatal circumcision, including the controversy. Introduced by Goldstein Manufacturing Company in the 1930s, the Gomco Clamp is the most widely used circumcision instrument and, according to Elliot Grossman, M.D., has done much to encourage neonatal circumcision. The vertical post and bell are placed over the glans and the foreskin is pulled over the outside of the bell. Mogen Clamp.

A comparison of the Mogen and Gomco clamps in combination

Patient 21 - GOMCO clamp. Circumcision Surgery - Before And After Pictures. For adult circumcision, I use the sleeve resection technique in which the foreskin is removed as a single ring of tissue utilizing a scalpel. In my opinion, this gives a symmetrical, fine incision line. In addition to a refined scar line, this technique allows the final. Circumcision Clamp Sklar® Mogen Stainless Steel. Sklar's® Pediatric Mogen Circumcision Clamp is used for circumcision p The opening for this instrument is 2.5mm #1119619; Fine Surgical #28-854; Circumcision Clamp Gomco® 1.1 cm Chrome-plated Brass. These chrome-plated circumcision clamps are designed to permit a singl

Comparison of newborn circumcision: Mogen vs

  1. This is Mogen Circumcision - Patient Demonstration by Shanley Deal on Vimeo, the home for high quality videos and the people who love them
  2. The most common devices used are the GOMCO (acronym for Goldstein Manufacturing Company) introduced in 1934, The Mogen clamp introduced in 1954, and the Hollister PlastiBell clamp introduced in 1950. Each one of these creates a pressure bond to hold together the skin edges so that their is no need for sutures
  3. This is Mogen Clamp Circumcision by hpmi on Vimeo, the home for high quality videos and the people who love them. SOC - Circumcision (5 Videos) Use your browser back button to return to the Circumcision module. Mogen Clamp Circumcision 8 years ago. This is Mogen Clamp Circumcision by hpmi on Vimeo, the home for high quality videos and the.
  4. Chan PS, Penna FJ, Holmes AV. Gomco Versus Mogen? No Effect on Circumcision Revision Rates. Hospital Pediatrics. 2018;8(10):611-61
  5. Shield and clamp. Doctors also use the Mogen and Gomco clamp in adult male circumcisions. A doctor can use several other devices as part of a shield and clamp method
  6. The most commonly utilized techniques used in the newborn nursery setting are the Gomco clamp, the Mogen clamp, and the Plastibell. While all of these can be used in the operating room, the free-hand circumcision using either the sleeve technique or the dorsal-ventral slit technique is most commonly used
  7. Techniques used vary from doctor to doctor, but three methods are common in the U.S.: the Gomco clamp, the Mogen clamp, and the Plastibell, a ring attached to the penis underneath the foreskin.

Call to Action: Clinical trial of Mogen vs Gomco

The Gomco Clamp is more often used by physicians in hospitals, particularly as the device of choice in routine circumcisions. There are those who use the Mogen Clamp in hospitals as well. Both devices (if used) should only be used by those who know how to use them very well, as the potential dangers of each could be quite disastrous Compared to Gomco, Mogen was shorter (6.98 ±2.97 vs 3.65±1.84 minutes, P <0.001) and showed a significant decrease in percent cortisol change (p=0.045, Table 1). There were no significant differences in CRIES scores or bleeding complications. 166 maternal surveys were completed with 98.7% maternal satisfaction in Gomco vs 98.9% in Mogen The Mogen clamp is opened fully. A key step in Mogen circumcision is the safe placement of the clamp. To push the glans out of the way, the surgeon's thumb and index finger pinch the foreskin below the dorsal hemostat. The Mogen clamp is then slid across the foreskin from dorsal to ventral following along the same angle as the corona

A total of 168 maternal surveys were completed, with 98.7% maternal satisfaction in Gomco vs 98.9% in Mogen. There were no reports of bleeding after discharge or circumcision revisions in either group to date. CONCLUSION Mogen clamp is associated with less neonatal pain physiologically by significantly lower percentage change in salivary. With the Mogen clamp, a circumcision requires just one cut and is over in minutes. The Gomco and Plastibell devices require doctors to make multiple incisions, which takes more time and causes more pain, according to studies cited in the April issue of the Journal of Family Practice There are three different techniques used to perform a circumcision; the Gomco, Plastibell and Mogen method. 1. The Gomco clamp. The Gomco clamp is the most widely used method for infant male circumcision. The device includes a bell that is placed on the tip of the penis (glans) and the foreskin is pulled over it RESEARCH CRITIQUE PAPER undergoing Mogen and Gomco clamps. 2. The aims of the research are to develop an adequately measuring neonatal response score and compare the pain levels between Mogen and Gomco circumcision clamps techniques. 3. Little is known about pain assessment among infants undergoing Mogen and Gomco circumcision clamps. This study is significant because it is the largest. The type of clamp used affects the time taken for the procedure, being on average 81 seconds for the Mogen clamp and 209 seconds for the Gomco clamp [Kurtis et al., 1999]. In a head-to-head trial of length of procedure the Mogen took 12 minutes, compared with 20 minutes for the Plastibell [Taeusch et al., 2002]

CIRCLIST - Gomco and Mogen compare

  1. The GoMo study: a randomized clinical trial assessing neonatal pain with Gomco vs Mogen clamp circumcision. Sinkey RG, Eschenbacher MA, Walsh PM, Doerger RG, Lambers DS, Sibai BM, Habli MA. Am J Obstet Gynecol, 212(5):664.e1-8, 17 Mar 2015 Cited by: 6 articles | PMID: 2579462
  2. Common after Mogen: Scar line after a mogen clamp circumcision tends to be further torards base of penis than after gomco clamp, plastibell or sleeve resection circumci Read More Send thanks to the docto
  3. The Mogen clamp is opened fully. Clamps should be checked periodically to insure that the opening is no more than 3.0 mm, and sent for repair or discarded if they do open wider. A key step in Mogen circumcision is the safe placement of the clamp
  4. ; P=.0001.

The three major methods of circumcision are the Gomco clamp, the Plastibell device , and the Mogen clamp. Also, what is the best method for circumcision? Circumcision can be performed with the Gomco circumcision clamp, the Mogen circumcision clamp, or the PlastiBell circumcision. device. Each device works well, provides excellent results, and. All studies demonstrated that MC performed with Mogen clamp was faster. Three papers compared Mogen clamp with Gomco clamp, demonstrating that Mogen clamp causes less pain especially when combined with preoperative analgesia (either with DPNB plus EMLA and acetaminophen, RB plus sucrose, or EMLA plus sucrose) [36, 37, 39]

Re: Gomco vs. Mogen Brain Dump - groups.i

  1. At New York Urology Specialists we use ShangRing, which is an innovative circumcision clamp. Gomco clamp and PlastiBell clamps are commonly used for circumcision in newborns and babies. In the Jewish tradition, mohels use a different technique that is similar to the 'sleeve circumcision utilizing a Mogen Circumcision clamp
  2. They concluded that the Mogen clamp may be associated with less pain and discomfort and may be safer, faster, and preferred by the surgeon. 4,5 </P>There is only 1 randomized controlled trial that compares the Mogen clamp with the Gomco to evaluate neonatal pain. 6 This trial included 48 infant males and was conducted prior to the American.
  3. Bleeding was more common with the use of the Gomco clamp than with the Mogen clamp. Circumcisions performed with Gomco clamp represented 73.2% of the total complications compared with 26.8% with the Mogen clamp. There were no injuries to structures outside the prepuce or problems requiring medical treatment after discharge from the neonatal.
  4. A few hundred years ago, a plain Mogen shield was introduced to enhance the safety of Bris Milah. Most Mohalim use at least this basic shield for Bris Milah. Approximately seventy years ago, the Gomco clamp was introduced and became a standard tool for physicians who perform circumcision. Halachic authorities- Jewish legal authorities, strongly.
  5. Gomco clamp. Mogen Clamp. Plastibell. Taraclamp. Smartklamp. Forcep guided method. This method quite straight forward, but may removed too much of shaftskin or leaving too much of mucosal skin. Tight skin dilated, any adhesion removed. 2 artery forceps are used to grasped the foreskin at 3 and 9 o'clock position. The foreskin is stretched

The Mogen surgical procedure seems to be the less painful surgical intervention, when compared with Gomco clamp or PlastiBell device. Only 3 papers studied groups of at least 20 babies each with. Call to Action: Clinical trial of Mogen vs Gomco circumcision clamps at the Good Samaritan Hospital in Cincinnati, Ohio The TriHealth Good Samaritan Hospital in Cincinnati, Ohio, is currently running a clinical trial to find which is better, whether the mogen clamp or the gomco clamp, to perform newborn male circumcisions Depending on the operator, he may use a bronstein (Mogen) clamp or a Traditional Jewish shield, but will usually finish the procedural (circumcision) component in under a minute. A bris requires the entire foreskin to be removed, as well as the mucosal membrane beneath the foreskin to be completely removed from the circumference of the glans A Gomco clamp, otherwise known as a Yellen clamp, is a specialized clamp for performing circumcisions. It was invented by Hiram S. Yellen and Aaron Goldstein in 1934-1935. Gomco stands for the Goldstein Medical Company, the original manufacturer of the clamp. In a 1998 study, it was the preferred circumcision technique of 67% of US physicians Mogen clamp: ( mō'gen ), a circumcision instrument. [Hebrew star

Start typing, then use the up and down arrows to select an option from the list. Depending on the user selection user can also view top products related to the selection The Mogen circumcision clamp, invented in 1954, is the most dangerous device still in use. It was designed to be fast and easy to use, especially in religious ceremonies. However the Mogen doesn't give the head of the (glans) penis any protection from laceration or disfigurement Using a scalpel (e.g. #15 blade), cut the foreskin by applying the blade against the bell. Make the cut at the position where the bell and foreskin meet the hole in the base plate. Leave the clamp in place for 5 minutes (decreases risk of bleeding) Remove the Gomco Clamp. Unscrew the base clamp enough to free the bell The Pollock Technique™ can be used for babies, boys, and men of all ages, and consists of using a Mogen clamp under long-acting local anaesthetic. The Pollock Technique™ circumcision is a reliable and effective procedure for infants, older children, teens, and men that delivers a virtually painless circumcision The Mogen clamp, one of the three most common circumcision devices, was invented by Rabbi Harry Bronstein in 1954. [1] It has two flat blades that open approximately 3 mm. [2] The name Mogen clamp is a general term for a style of clamp; there are several different manufacturers of specific models

Mogen Clamp - Buy Mogen Clamp,Mogen Circumcision Clamps

ส่วน device method นิยมทำใน newborn คือ plastibell, mogen clamp, Gomco clamp Circumcision ในเด็กดมยาใช้ under mask ร่วมกับยาชาเฉพาะที่ penileblock หรือ field block ขั้นตอนท Mit welchen Begründungen treten Ärztinnen und Ärzte, die Ihren Sohn beschneiden wollen, an Sie heran und wie können Eltern sich gegen solche Versuche unwissender und/ oder geldgieriger Ärztinnen und Ärzte wappnen Over 70% New & Buy It Now. This Is The New eBay. Find Gomco Clamps Now

Harm of circumcision | CircWatchMogen Circumcision

Video: Re: Gomco vs. Mogen Brain Dum

Newborn Circumcision Techniques - American Family Physicia

McClowry, MD, Robert J., Journal Club: The GoMo study: a randomized clinical trial assessing neonatal pain with Gomco vs Mogen clamp circumcision (2016). Department of Family & Community Medicine Presentations and Grand Rounds The more frequently used Gomco clamp provides a superior cosmetic appearance in the neonatal period. However, glans injuries are rarely seen with the Mogen clamp, and although the Plastibell clamp can be easily used,[ 4 ] it is not generally preferred due to the longer stay of the device on the neonate penis compared the Mogen clamp with the Gomco clamp. The procedure time for the Mogen clamp was 1.9 times shorter than for the Gomco clamp in the first study (7.2 ± 0.32 vs 13.9 ± 0.32 min; P=.0001) and 2.5 times shorter in the sec-ond study (1.35 ± 0.32 vs 3.48 ± 1 min), thereby decreasing duration of pain.3,4 One of the RCT I'm a surgical tech and do not like the gomco clamps! I haven't ever heard of the other. In our area we have another clamp called a mogan and it's older than the gomco and to me looks less painful. It's only one piece unlike the gomco which can be put together wrong in the sterile department as there are different sizes

CircLeaks: Call to Action: Clinical trial of Mogen vsQualitative Research Critique Week 4 TemplateMogen Circumcision - YouTube

Gomco or Mogen for Newborn Circumcision: Is One Better

  1. utes to allow for hemostasis. The foreskin is then cut with ascalpel[5]. Mogen clamp It is a device with a slit-like space of 3 mm between two blades. The clamp is placed over the glans an
  2. ed to be more painful and took 2.5 times longer to complete the procedure compared with the Mogen clamp; the Mogen clamp was almost twice as fast as the PlastiBell device.
  3. It is terribly troubling that a lot of parents are told that the Plastibell form of circumcision is less painful or less traumatic for a newborn. For this surgery, a Plastibell is used rather than a Gomco Clamp or Mogen Clamp. Plastibell may sound like a more inviting tool to use on a highly sensitive penis than Clamp
  4. Gomco and Plastibell tend to be higher cuts, though lower (closer to the head) is possible. Lower cuts are much more common in adult circumcisions where there is more potential for drastic color change. Gomco clamps are known to leave a relatively wide, dark ring, while Mogen and some freehand methods can leave a v-shape scar

Gomco Versus Mogen? No Effect on Circumcision Revision

Gomco clamp Patient Care Magazine 1978; March 15:82-85. [CIRP Note: The following reference dicusses the use of anesthesia with the Gomco clamp circumcision. CIRP cautions that the anesthesia used reduces but does not eliminate pain.] Peleg D, Steiner A. The gomco circumcision: common problems and solutions With both clamp devices (Gomco and Mogen), hemostasis is dependent on the adequacy of the crush injury. It should be noted that tissue edema puts increased stress on a crushed edge and can lead to oozing, so care should be taken during the procedure to minimize trauma of the sensitive foreskin. Keeping the instrument used to remove adhesions in. The Gomco clamp, the Mogen clamp, and Unicirc are surgical instruments. [8] Circumcision devices remain on the penis for 4 to 7 days and either spontaneously detach or are removed surgically at a subsequent visit. [9] Plastibell, Prepex, Shang Ring and other plastic rings are all circumcision devices, also known as 'in situ' devices. [8 The three most commonly used circumcision procedures in the United States are the Gomco clamp, Plastibell device, and Mogen clamp, according to a 2012 report in the journal Pediatrics The Gomco Clamp. A special instrument called a probe is used to separate the foreskin from the head of the penis (they are usually joined by a thin membrane). Next a bell-shaped device is fitted over the head of the penis and under the foreskin (an incision may be made in the foreskin to allow this). The Mogen Clamp. Again, the foreskin is.

2 PCS Gomco Circumcision Clamp 1

The GoMo study: a randomized clinical trial assessing

Gomco Clamp. With the Gomco clamp method, the physician administers local anesthetic and then stretches foreskin over the bell part of a three-part clamp. The physician then tightens the clamp over the foreskin and cuts the excess skin away. The Mogen clamp is the fastest and least painful method of circumcision. The procedure begins with a. Gomco Clamp: Circumcision with the Gomco clamp is the most common type in America. First, doctors separate the foreskin from penis head with a probe. Mogen Clamp: After the foreskin is. Use of the Gomco clamp was more likely to result in bleeding than was the Mogen clamp, 5.69% (34/598) vs 2.96% (14/473), P=.03. Statistical significant difference was noted between pediatricians complication rate (11.49%), compared to OB/GYN physicians (3.08%) ( P =.0002)

Gomco Clamp Technique Newborn Nursery Stanford Medicin

The advantages of The Gomco Clamp are that it produces a very good cosmetic result, with an even scar line. It is possible to remove more skin with the clamp than with the Plastibell. If that is important to you and you don't want a little roll of skin behind the rim of the glans in the flaccid position, then you may prefer this method One study has compared the results of Plastibell clamp vs. classic dissection circumcision, and both were found to have a similar occurrence of immediate complications such as bleeding . Another study has shown that a worn out, and overused Gomco clamp has less of a vessel crushing effect, hence more bleeding [ 26 ] The circumcision related cosmentic abnormality rate was 1.6% when using a Mogen clamp and 2.4% when using a Gomco clamp, but htis was not statisticallly significant (p=0.21). Rates did not differ by age of infant nor hospital (used as proxy for training level). Abnormailities identified were redundant foreskin (40%), adhesions (25%), both (35%)

Circumcision surgical procedure - Wikipedi

Gomco clamp and the Mogen clamp [12-16]. All tech-niques cause similar amounts of tissue destruction [16]. The aim of this review is to examine and summarize all studies in literature since the year 2000 that have com-pared various methods of analgesia during newborn/infant MC 5. Circumcisions leave unique marks. Most circumcisions in the United States are done with one of three devices: the Mogen Clamp, the Plastibell and the Gomco clamp. The Mogen clamp is a. CONCLUSIONS: Infants circumcised with the Mogen clamp and combined analgesia have substantially less pain than those circumcised with the Gomco clamp and lidocaine-prilocaine cream. Because of the immense pain during circumcision, combined local anesthesia and analgesia using the Mogen clamp should be considered

gomco clamp circumcision: Does anywhere - Men's Health

shorter for infants circumcised using the Mogen clamp compared with those circumcised with the Gomco clamp (mean [SD], 55.0 seconds [12.6] vs 576.6 seconds [64.11])(P<.001). The facial activity scores recorded during circumcision are shown in Figure 1. The scores were significantly lower (P<.001) for infants in group 1 The Gomco clamp method and Mogen clamp device are also used for adult male circumcisions. To do this, your doctor will place a protective cap over the head of your penis The Mogen clamp was associated with the least discomfort and shortest application time (mean time for Mogen was 81 seconds v 209 seconds for the Gomco) ( Table 3)

Circumcision Gomco. A circumcision (sir cum SI zhun) is surgery to remove the foreskin (extra skin) from. around the end of the penis. Your baby will be awake and will have an injection (a shot) at the base of the penis to. numb the area. He may also be given a sugar water solution (Sweet-ease ®) by mouth to prevent discomfort Plastibell Gomco Clamp Mogen Clamp. ZSR Circumcision in Bangalore. The World Health Organization has endorsed a device from China that makes it easier and faster to perform surgical circumcisions. The device - which comes in 20 different sizes- consists of two plastic and rubber rings. ZSR circumcision is a revolutionary development in the. When using the Gomco clamp or Plastibell, the choice of device size depends on the diameter of the glans rather than penile length.22 The Gomco clamp ranges from 1.1 to 1.6 cm, and the Plastibell. plastibell circumcision vs traditional; October 10, 2019. circumcision healing chart What are some of the advantages to using the mogen clamp for circumcision? - the quickest, and therefore least painful, of the three procedures. - Does not leave a foreign body at the circumcision site vs. Plastibel CONCLUSIONS: Infants circumcised with the Mogen clamp and combined analgesia have substantially less pain than those circumcised with the Gomco clamp and lidocaine-prilocaine cream. Because of the immense pain during circumcision, combined local anesthesia and analgesia using the Mogen clamp should be considered. PMID: 10850512, UI: 2030668 1 Gomco Clamp 1.1 CM. 1 Gomco Clamp 1.2 CM. 1 Gomco Clamp 1.3 CM. 1 Gomco Clamp 1.6 CM. 1 Gomco Clamp 1.45 CM. 1 Gomco Clamp 2.1 CM. 1 Gomco Clamp 2.6 CM. 1 Gomco.